Honeywell Vista 20p Installation Manual
Alarm Grid Home Security has provided this pdf with the permission and courtesy of Honeywell. Alarm Grid is a home security product and alarm monitoring company that loves its customers. We have a strong appreciation of the DIY community, and want to make sure that we not only provide the best products and services out there but we also want to make sure that resources like these Honeywell product pdfs are easily accessible so that or curious customers can find what they need when they need it. Honeywell Vista 15p Honeywell Vista 20P Install Guide • 1. ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems Installation and Operation GuideK5305-1V9 2/11 Rev. B • RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations for the Location of Fire and Burglary Detection Devices Help Provide Proper Coverage for the Protected Premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Associations (NFPA) Standard #72 noted below.
Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: For minimum protection a smoke detector should be installed outside of each separate sleeping area, and on each additional floor of a multi-floor family living unit, including basements. The installation of smoke detectors in kitchens, attics (finished or unfinished), or in garages is not normally recommended. For additional protection the NFPA recommends that you install heat or smoke detectors in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements and attached garages. In addition, we recommend the following: • Install a smoke detector inside every bedroom where a smoker sleeps. • Install a smoke detector inside every bedroom where someone sleeps with the door partly or completely closed. Smoke could be blocked by the closed door. Also, an alarm in the hallway outside may not wake up the sleeper if the door is closed.
• Install a smoke detector inside bedrooms where electrical appliances (such as KITCHEN portable heaters, air conditioners or BEDROOM BEDROOM TV ROOM KITCHEN DINING BDRM DINING humidifiers) are used. LIVING ROOM BDRM • Install a smoke detector at both ends of a BEDROOM hallway if the hallway is more than 40 LIVING ROOM BEDROOM feet (12 meters) long. • Install smoke detectors in any room where Smoke Detectors for Minimum Protection an alarm control is located, or in any room Smoke Detectors for Additional Protection where alarm control connections to an AC BEDROOM Heat-Activated Detectors source or phone lines are made. If detectors are not so located, a fire within TO BEDROOM BR BEDROOM the room could prevent the control from KTCHN reporting a fire or an intrusion. GARAGE LVNG RM. CLOSED DOOR THIS CONTROL COMPLIES WITH NFPA BASEMENT REQUIREMENTS FOR TEMPORAL PULSE floor_plan-001-V1 SOUNDING OF FIRE NOTIFICATION APPLIANCES.
Nissan Terrano 2 Service Manual Download. Recommendations For Proper Intrusion Protection For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building.
ADEMCO VISTA SERIES. VISTA-20P / VISTA-20PSIA. VISTA-15P / VISTA-15PSIA. Security Systems. Programming Guide. K5305-1PRV9 3/15 Rev A. Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: For minimum protection a.